12V 10A 120W AC/DC Switching Power Supply with CE UL FCC Built-in PFC
This is a 120W series switching power supply designed according to IEC/EN/UL62368-1 and IEC/EN61558-1 desktop style with C8,C14 outlet or fixed cable for input. Built-in active power factor correction circuit with PF>0.9. The maximum output current is 10A and the maximum voltage is 48Vdc suitable for the applications of Infomation Technology Equipents, Audio & Video equipments, Consumer Electronics Products, Security Products and so on.
General Specifications:
Input | 90~264VAC 50/60Hz |
Power Factor | >0.9 |
AC plug type | C8, C14 |
Output | 12VDC 10A |
Output cord | 1.0M |
Output connector | Available as below picture list |
Efficiency | 88% Typical |
Standby Power | <0.21W |
Protections | Short Circuit / Over Voltage / Over Temperature |
Safety Standard | UL/IEC/EN62368-1, IEC/EN61558, GB4943 |
Certificates | CE, UL/cUL, GS, PSE, SAA, RCM, C-Tick, KC, CQC, UKCA, RoHs, REACH |
Working Temp. | 0~+40 ºC |
Storage Temp. | -20~+80 ºC |
MTBF | 50000 hrs Min. |
Dimensions | 172.7 x 72.7 x 33mm |
Weight | 700g |
Warranty | 2 Years |
Reliability Requirements
1. Vibration Test:
10 to 300Hz sweep at a constant acceleration of 1.0G(Breadth: 3.5mm) for 1Hour for each of the perpendicular axes X, Y, Z
2. Drop in Test:
Drop height: 1m, and drop onto the hardwood with thickness of 20mm, and the hardwood shall be placed on the cement base or equivalent
On elastic ground, once on each side.
3. Burn-in
The power supply shall be burn-in for 4 Hours under normal input and 80% rated load at 40ºC .
Safety Requirements
1. Dielectric Strength(Hi-pot)
Primary to Secondary: 3000Vac / 10mAMax / 60 second
Primary to Secondary: 3300Vac / 5mAMax /3S
2. Leakage Current
0.25mAmax. at 264Vac / 50Hz
3. Insulation Resistance
50MΩ min. at primary to secondary add 500Vdc test voltage
EMI/EMS Standards
EMI: FCC Part15 class B
EN55022
EN61000-3-2
EMS:
a. ESD (EN61000-4-2):
Air discharge: +/-8KV : B
Contact discharge: +/-4KV : B
b. Radiated electromagnetic field susceptibility (EN61000-4-3):
3V/m (r.m.s) / 80-1000MHz,80%AM(1KHz) sine-wave : A
c. Electric fast transients(burst) immunity requirement (EN61000-4-4):
AC-input / 0.5KV : A
AC-input / 1.0KV : B
d. Surge capability requirement (EN61000-4-5): Differential mode 1KV: A
e. Induced radio frequency fields conducted disturbances immunity requirement:
3V / 0.15-80 MHz,80%AM(1KHz) : A


Certificates:

Company Introduction:

Test Report:


Exhibitions:

More ProductsFQAQ: What is your MOQ?
A: Generally our MOQ for each model is 500PCS, we can discuss in details if you have special requirements, like big quantity for the whole order but small quantity for each model.
Q: How about the warranty of your product?
A : Generally we offer 24-Months warranty for our products. Quality is the most important for long-term business partnership, and it is also our company aim to offer high quality and guaranteed products to help our clients expand their target markets.
Q: How can I finish my payment?
A: T/T, L/C, Western Union are all acceptable, PayPal is also OK.
Q: How can I get detailed specifications about this product? Do you have catalogue and price list?
A: We have all the specifications, catalogues and price lists for each model. Welcome to contact us for detailed information via the contact ways mentioned below anytime!
Q: What standard of your product meet?
A: Most of our products meet IEC/UL/EN62368/61558 and some meet IEC60335 / 60601.
Q: Will each of your product tested before shipment?
A: Yes, each product has been tested in every step. Each product has been done burn-in test for minimum 2 hours and the completed tests have been done before and after the burn-in test!
Q: What's the lead time?
A: Sample :5-10 business days. Mass production: 15-25 business days, depends on the order quantity and hot season or not.
Q: Could you customize product for us ?
A: Yes, ODM is one of our main services.