• 1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
  • 1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
  • 1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
  • 1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
  • 1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
  • 1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank

After-sales Service: Yes
Material: Q235 Steel
Warranty: 12 Months
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank pictures & photos
1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
US $14,585-16,050 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
RT1000KWLB
Protection Level
IP23 Indoor/IP55/Customized
Voltage
AC400V/630V/Customized
Rated Load
1000kw
Application
Generator/UPS Load Test
Customized
Customized
Surface Treatment
Powder Coating
Name
Load Bank
Power Capacity
1000kw
Rated Voltage
AC400V/415V/Customized
Control Mode
Manual
Design
Outdoor
Frequency
1.0
Transport Package
Film Wrapping/Wooden Box
Specification
Reference the specification following
Trademark
Rata
Origin
China
HS Code
9030899090
Production Capacity
5 Set/Month

Packaging & Delivery

Package Size
210.00cm * 151.00cm * 195.50cm
Package Gross Weight
1850.000kg

Product Description

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
Product Description

1000KW AC Dummy Air Cooling Resistive Generator Load Test Load Bank

HS Code: 9030899090
Certificates: ISO9001:2015,ISO14001:2015,ISO45001:2018,CE

 

>LOAD BANK SPECIFICATION
1000kW Resistive Load Bank Data Sheet
Model No. RT1000KWLB
Load type 100% Resistive
Tested power 400VAC(customized available),3P4W,connected with copper bar
Work power 380VAC,3P4W,connected with terminal
Frequency 50 or 60Hz
Capacity 1000kW
Power factor 1.0 
Load accuracy ±3%
3Phase balance Unbalance: ≤3%
Insulation F
Protection level IP55,IP 23 when using
Time rating Continuous design
Control mode Manual control
Design Outdoor design
Resistive load Min.step: nominal 1kw resolution or customized
Steps: 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW×9
8020 NiCr alloy finned resistor
Cooling system Forced air cooling,horizontal air inlet/outlet with axial fan,noise≤85dB(3m)
Functions Real time display of current/voltage/power/power factor/frequency
Load protection/ function Low air volume/high temperature/fan interlock protection/short circuit/over
current/emergency stop/fan phase sequence automatic transfer protection/
operational indicator/fan operation indicator/load switch
Enclosure RAL7035 or customized/Q235 cold rolled steel plate.
Transportation Forklift holes
Dimension 2102mm*1510mm*1955mm
Weight 1850kg
Packing Woden case + wooden pallet
Temperature -20ºC to 50ºC
Humidity up to 100%
Altitude up to 4000m
Atmospheric pressure 86 to 106kPa
 
Detailed Photos

1000kW load bank manual control + outdoor design picture
1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank

Packaging & Shipping
1000kW load bank will be packed with wooden case + wooden pallet for movement
Company Profile

> Established in 2013
> 1600 square meters production shop
> 120 square meters office
> 22 employees
> 25 patents for load bank
> 10 years load bank design,production,service experience
> 8 computer software copyrights
> 7 stars after sales service certificate

> ISO9001:2015,ISO14001:2015,ISO45001:2018,CE certificates
> Clients come from include but not limited: South Korea,India,Kazakhstan,Indonesia,UAE,Denmark,France,Rwanda,New Zealand,Chile,Paris,Peru,America..

> DESIGN
Rata has professional technical team,they have 3~15 years load bank design experience, capable to design low and medium voltage and 2kW~10000kW,5kVA~7000kVA single load bank. We can design the load bank as per customers' reuquirement and based on related standards.

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
> PRODUCTION
Rata has professional technical team and skilled workers, all the production workers has 1-10 years load bank production experience. All the products produced based on the technical drawings,related standard(ISO9001),production /test/metering equipment(35 types).

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
> FACTORY TEST/ONSITE SERVICE
All rata produced products will be tested based on related standards,rules and process before delivery. Test report and video will be supplied to customer. Rata also supply charged onsite service include onsite commissioning and training.

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
> QUALITY CONTROL
In the design, production, and inspection process of the system, the seller takes the following measures to ensure that the system quality is qualified and can meet the needs of users:
> The design and production of the system are entirely based on the technical agreement agreed upon by both parties.
> Before production, provide the equipment outline drawing to the user, and after confirmation and approval, production can be carried out based on the drawing.
> During the production process, a specialized inspection department conducts strict quality inspections of the raw materials used in the system.
> Conduct full process quality tracking during component processing, assembly, and debugging, and establish product archives.
> Ensure that all accessories are advanced, brand new, complete, and reasonably arranged, in accordance with relevant national standards. The interior of the equipment is clean, the wiring is neat, all wiring conforms to the drawings, and the interfaces and switches are correctly and clearly marked.
> Strictly follow the requirements of the drawings, relevant standards, and specifications to verify the functionality and parameters of the system, ensuring that the final product can achieve all the agreed content in the technical agreement.

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
> AFTER SALES SERVICE
Rata supply 7×24 hours after sales service. Rata promises to provide lifelong technical services, including the following:
> The system quality assurance period is calculated from the date of system acceptance and lasts for 12 months.
> Rata shall provide free maintenance for any quality issues that arise within the warranty period of the system.
> After encountering problems, users are guaranteed to respond within 2-8 hours based on the time difference.
> If it is necessary to dispatch technical personnel to the site to solve the problem, Rata shall ensure that they arrive at the site within 24-72 hours. Service personnel shall not evacuate until the problem is resolved.
> Users can permanently enjoy free technical consulting services.
> Save complete product technical archives for users.
> After the end of the 12 months warranty period, we provide users with lifelong paid maintenance services at a cost only.
> The supplier is required to provide a cost price list of conventional spare parts, such as resistors and contactors.
> If necessary, the seller will provide users with the most favorable price for system upgrades and renovations.

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank

> CERTIFICATES
We supply ISO9001:2015,ISO14001:2015,ISO45001:2018 and CE certificates. If need other certificates,let me know.

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
> CUSTOMER VISITATION
You are warmly welcome to visit us,I will go to Mianyang/Chengdu Airport to pic you up and arrange following thing to make sure you will have a happy trip.

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank

FAQ

1:What is the HS code?
9030899090

2:What is the language of the operation instruction?
Generally the language will be English,but it can be your local language based on your help to translate it.

3:What is the language of the operation panel and control software?
Generally the language will be English,but it can be your local language based on your help to translate it.

4:What is the guarantee time?
Generally12 months start from commissioning on site.

5: Can you supply Certificate of Original?
Yes.

6: What are the brands for the components?
Contactor: ABB/Schneider,Breaker: ABB/Schneider,Fuse: Delixi,PLC: Siemens,Fan: Fengmai,Resistor: Zhuxing all are first level brand at international and China market.

7: What is the noise?
Actually noise:≤80dB(1m)

8:Do you support OEM?
Yes.

9:Do you support customized control software?
Yes.

10:What is the after sales service time?
We supply 7×24hrs after sales service.But maybe there is some delay caused by the time zone restrictions.

11:Who should we contact for the after sales service?
You may contact the salesman for the after sales service directly caused by the language restrictions.

12:What is the delivery time?
The delivery time based on the power capacity and quantity.

13:How to operate the load bank as "local-off-remote"?
There is indication for "local"and"remote" control on the local panel.And it is controlled by key. Turn the key to "local" direction,then can control the load bank manually;turn the key to "remote",then can control the load bank remotely.

14:Does it complicated to use the remote control software?
It is say to use the control software,we can supply the operation video for your reference.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank pictures & photos
1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
US $14,585-16,050 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
24
Year of Establishment
2013-09-09