The Best Calibrator Products

TD1855 Multi-function Calibrator Summary TD1855 is a multi-function calibrator, integrates AC\DC voltage source, AC\DC current source, DC resistance source, etc. The accuracy class is 0.05. It's applied to calibrating 3.5 digits multimeter, voltmeter, ammeter, ohmmeter, power meter. Features DC voltage output: 20 mV ~ 1100 V DC current output: 2 &mu;A ~ 22 A(33 A is optional) AC voltage output: 20 mV ~ 1100 V AC current output: 200 &mu;A ~ 22 A(33 A is optional) Sinusoidal wave frequency: 45 Hz ~ 1100 Hz Simulated DC resistance: 10 &Omega; ~ 220 M&Omega; 2 MHz square wave frequency output Phase output AC/DC power output Remote adjustment (optional) Clamp meter calibration (optional) Transducer calibration(optional) Application &#9734; Calibrate AC\DC electrical measuring instruments DCV output: 20 mV ~ 1100 V DCI output: 2 &mu;A ~ 22 A\33 A ACV output: 20 mV ~ 1100 V, 45 Hz ~ 1100 Hz ACI output: 200 &mu;A ~ 22 A\33 A, 45 Hz ~ 1100 Hz RES output: 10 &Omega; ~ 220 M&Omega; Frequency output: 1 Hz ~ 2 MHz Calibrate digital multimeter, AC/DC voltmeter, AC/DC ammeter, DC ohmmeter, frequency meter. &#9734; Calibrate AC\DC power meters Calibrate DC power meter, real power meter, phantom power meter, apparent power meter, power frequency phase meter and power factor meter. &#9734; Calibrate clamp ammeter (optional) Equivalent to 1000AT current through input 20A current to the 50T Coil, which is suitable for calibrating DC clamp meters. &#9734; Calibrate AC/DC Transducer (optional) DC small-signal measurement. (Vmax: 12 V, Imax: 24 mA) Calibrate the proportional error of AC/DC voltage/current transducer. Appearance &#9734; Front\Side Panel Item Description 1 LCD touch screen. 2 Operation panel. 3 Simulated DC resistance output terminals. 4 AC/DC voltage output terminals. 5 AC/DC current output terminals. 6 Handle: used for carrying instruments. 7 Input terminals for DC transducer. &#9734; Rear Panel Item Description 1 Pulse frequency output terminals. 2 Remote box interface. 3 RS232 communication interface. 4 Chassis ground binding post. 5 AC 220V power interface. 6 Cooling vents. Characteristics &#9734; Multiple output\adjustment methods "Direct output" mode: the value output can be set directly by physical key or touch screen. Calibration of the analog pointer meter usually needs to test scale by scale, especially "differences between rising and falling" (the change caused by the rise and fall of the calibration point). Remote box can realize the coarse and fine adjustment of current or voltage. Specifications 6.1 DC Voltage/Current Output Range Resolution Stability (&plusmn;&plusmn;%/min) Accuracy &plusmn;(ppm*RD+ppm*RG)[1] Max burden (mA) Ripple Factor(%) 200 mV 1 &mu;V 0.01 300 + 200 300 <0.5 2 V 10 &mu;V 0.01 300 + 200 500 <0.5 10 V 100 &mu;V 0.01 300 + 200 500 <0.5 30 V 100 &mu;V 0.01 300 + 200 800 <0.5 100 V 1 mV 0.01 300 + 200 300 <0.5 300 V 1 mV 0.01 300 + 200 100 <0.5 600 V 1 mV 0.01 300 + 200 50 <0.5 1000 V 10 mV 0.01 300 + 200 30 <0.5 Range Resolution Stability (&plusmn;&plusmn;%/min) Accuracy &plusmn;(ppm*RD+ppm*RG) Compliance Voltage (V) Ripple Factor(%) 20&mu;A 100pA 0.01 300 + 200 10 <0.5 200&mu;A 1 nA 0.01 300 + 200 9 <0.5 2mA 10 nA 0.01 300 + 200 9 <0.5 20mA 100 nA 0.01 300 + 200 9 <0.5 200 mA 1 &mu;A 0.01 300 + 200 9 <0.5 2 A 10 &mu;A 0.01 300 + 200 3.5 <0.5 10 A 100 &mu;A 0.01 300 + 200 2.5 <0.5 20 A (30 A)[2] 100 &mu;A 0.01 300 + 200 2.5 <0.5 Note[1]: RD is the reading value, RG is the range value; Note[2]: The 30 A range is optional. Voltage output range: 20 mV ~ 1100 V Current o

Related Hot Products By Calibrator