Breaking Capacity: | High Voltage Circuit Breakers |
---|---|
Operation: | Electric Type |
Speed: | High-Speed Circuit Breaker |
Arc-extinguishing Medium: | Air |
Installation: | Fixed |
Structure: | MCCB |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Key Information
WCM1L
Pole: 2P, 3P, 3P+N,4P
Voltage: AC230V/400V
kA: 35-75kA
Inm(A): 100,125, 250, 400, 800
In(A): 10A-800A
Main technical parameters
Model | WCM1L-125 | WCM1L-250 | WCM1L-400 | WCM1L-800 | |||||||
Frame current Inm (A) | 125 | 250 | 400 | 800 | |||||||
Rated current In (A) | (10), 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 | 100, 125,140, 160, 180, 200, 225, 250 | 225, 250, 315, 350, 400 | 400, 500, 630, 700, 800 | |||||||
Pole (P) | 2 | 3 | 4 | 2 | 3 | 4 | 3 | 4 | 3 | 4 | |
Rated insulation voltage Ui (V) | AC800 | ||||||||||
Rated operation voltage Ue (V) | AC400 | ||||||||||
Rated impulse withstand voltage Uimp (V) | 8000 | 8000 | 8000 | 8000 | |||||||
Flashover distance (mm) | ≯50 | ≯50 | ≯100 | >100 | |||||||
Breaking capacity rank | M | H | M | H | M | M | |||||
Ultimate short circuit breaking capacity Icu (kA) | AC 400V | 35 | 50 | 35 | 50 | 50 | 50 | ||||
Operation short circuit breaking capacity Ics (kA) | AC 400V | 22 | 35 | 22 | 50 | 35 | 35 | ||||
Rated residual operation current IΔn (mA) | Non-delayed type | 100/300/500 | - | ||||||||
Delayed type | 100/300/500 | 300/500/1000 | |||||||||
Rated residual non-action current IΔno (mA) | IΔn/2 | ||||||||||
Rated residual short circuit connecting (breaking capacity IΔm (kA) | Icu/4 | ||||||||||
Operation performance (times) | Power-on | 1500 | 1000 | 1000 | 1000 | ||||||
Power-off | 8500 | 7000 | 4000 | 4000 | |||||||
Shunt release | > | > | > | > | > | > | > | > | |||
Under voltage release | > | > | > | > | > | > | > | > | |||
Leakage alarm unit modular | > | > | > | > | > | > | > | > | |||
Auxiliary contact | > | > | > | > | > | > | > | > | |||
Alarm contact | > | > | > | > | > | > | > | > | |||
Motor-driven operation mechanism | > | > | > | > | > | > | > | > | |||
Rotating handle operation mechanism | > | > | > | > | > | > | > | > |
Notes: 1. It includes vertical and horizontal installation of ultimate breaking and flashover distance;
2. Three poles circuit breaker of this series connects with three phase loading, of which can not be with neutral line, otherwise the circuit breaker will make fault operation;
3. Three poles circuit breaker of this series connects with three phase loading, phase line at left pole, neutral line at right pole not the middle pole.
General
WCM1L series residual current protection moulded case circuit breaker (RCCB for short) is one new breaker researched and developed by advanced international design and manufacture technology of the company. The rated insulation voltage 800V, applies AC50Hz, rated operation voltage 400V, rated operation current upto 800A for infrequent switch of the line and infrequent start of the motor. RCCB has protection functions to overload, short circuit and under voltage, to protect the line and power device from deamge, also make protection to the fire caused by grounding fault at long time that undetected under over current.
RCCB is divided into type M (higher breaking), and type H (very high breaking), has features of smal volume, high breaking, short flashover, vibration resistance, etc.,
WESTHOMES ELECTRICS GROUP(L.L.C),A professional supplier of power transmission and distribution equipment, is engaged in the solutions and relative equipment for power transmission and distribution system of civil, commercial,industrial and construction uses, as well as the full range of service for endplants to mansions, infrastructure facilities and industrial fields. We produce high and low voltage electric equipment, electric kit, high and low voltage electric components, terminal power distribution system for construction, instruments and meters, as well as electronic products, which are used in electric power system. Our business covers more than 60 countries and regions.
WESTHOMES,supportecd by innovative ideas and skilled professors, has developed a highly effcient operation system from technical R&D ,production, marketing netwrok and customer service. This operation system based on ISO9001,together with other relative international product certifications make our products and service highly recognized and respected by craft borthers and users in European and American market.Focusing on the development of internation electric technology, we always timely assimilate the world advanced electric tehnology, and present suitable new products in response to cusomers' requirments.
Along with the development and consummation of our several production bases in Southeat Asisa, we are committed to providing you with more electric products in more favorable prices.We welcome clients all over the world to purchase and act on agency of WEST HOMES electric products, and sincerely hope that our quality products and service will bring you more business opportuniteis and profitability.
Frequently Asked Question (FAQ)
Q: About the companySuppliers with verified business licenses