Type: | Hall Type |
---|---|
Output Signal Type: | Analog Output |
Production Process: | Integration |
Material: | Plastic |
Accuracy Grade: | 1.0G |
Application: | Motor Controller |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Electrical data(Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF) |
Type Parameter |
TKC50 EKAA1210 |
TKC100 EKAA1210 |
TKC300 EKAA1210 |
TKC400 EKAA1210 |
TKC500 EKAA1210 |
Unit |
(Ipn) Rated current(Ipn) |
±50 | ±100 | ±300 | ±400 | ±500 | A |
(Ip) Measuring range(Ip) |
-50-+100 | -100-+200 | -300-+600 | -400-+800 | -500-+1000 | A |
(Io) Rated output (Io) |
@Ip=±Ipn 10±10±1% | mA | ||||
Supply voltage |
+12±10% | V | ||||
Power Consumption |
+35+Io | mA | ||||
Offset current |
@Ip=0 0.1 | mA | ||||
Magnetic offset |
@Ip=±Ipn-0 0.1 | mA | ||||
Offset drift |
-40 to +85ºC ≤±0.005 | mA/ºC | ||||
output drift |
-40 to +85ºC ≤±0.005 | mA/ºC | ||||
Linearity |
@Ip=0-±Ipn ≤1 | %FS | ||||
Response time |
@50A/μS, 10%-90% ≤5 | μS | ||||
Bandwidth |
@DC,(-3dB) 25 | KHz | ||||
Galvanic isolation |
@ 50HZ,AC,1min 2.5 | KV |