Application: | Power, Electronic, Instrument, Lighting, Rectifier |
---|---|
Phase: | Three |
Core: | Core-type Transformer |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Rated capacity(KVA) | Voltage Combination and tap range | connection of transformer winding | No-load loss(W) | Load loss (W) | No-load current (%) | Short circuit impedance (%) | ||
High voltage (KV) |
High voltage tap range ( %) |
Low voltage (KV) |
||||||
30 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 |
11 10.5 10 6.3 6 |
±5% ±2x2.5% |
0.4 0.69 |
Yyn0 Dyn11 |
100 130 150 180 200 240 280 340 400 480 570 680 810 960 1150 1360 1640 1960 2310 |
630/600 910/870 1090/1040 1310/1250 1580/1500 1890/1800 2310/2200 2730/2600 3200/3050 3830/3650 4520/4300 5410/5150 6200 7500 10300 12000 14500 19800 23000 |
2.3 2.0 1.9 1.9 1.8 1.7 1.6 1.5 1.4 1.4 1.3 1.2 1.1 1.0 1.0 0.9 0.8 0.8 0.7 |
4 4 4 4 4 4 4 4 4 4 4 4 4.5 4.5 4.5 4.5 4.5 5 5 |
Rated capacity(KVA) | Voltage Combination and tap range | connection of transformer winding | No-load loss (W) |
Load loss (W) | No-load current (%) | Short circuit impedance (%) | ||
High voltage (KV) |
High voltage taps range (%) | Low voltage (KV) |
||||||
50 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 |
20 22 24 |
±5% ±2x2.5% |
0.4 |
Yyn0 Dyn0 |
210 290 340 360 430 510 610 730 860 1040 1230 1440 1760 2120 |
1270/1210 2120/2020 2500/2380 2970/2830 3500/3330 4160/3960 5010/4770 6050/5760 7280/6930 8280 9900 12150 14670 17550 |
2.00 1.80 1.70 1.60 1.50 1.40 1.40 1.30 1.20 1.10 1.00 1.00 0.90 0.80 |
6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 |
Rated capacity(KVA) | Voltage Combination and tap range | connection of transformer winding | No-load loss(W) | Load loss (W) | No-load current (%) | Short circuit impedance (%) | ||
High voltage (KV) |
High voltage tap range ( %) |
Low voltage (KV) |
||||||
30 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 |
6 6.3 6.6 10 10.5 11 |
±5% ±2x2.5% |
0.4 |
Dyn11 Yzn11 Yyn0 |
80 100 110 130 150 170 200 240 290 340 410 480 570 700 830 970 1170 |
630/600 910/870 1090/1040 1310/1250 1580/1500 1890/1800 2310/2200 2730/2600 3200/3050 3830/3650 4520/4300 5410/5150 6200 7500 10300 12000 14500 |
1.8 1.6 1.6 1.5 1.4 1.4 1.3 1.2 1.2 1.1 1.1 1.0 0.9 0.8 0.8 0.7 0.6 |
4 4 4 4 4 4 4 4 4 4 4 4 4.5 4.5 4.5 4.5 4.5 |
Dyn11 Yyn0 |
Rated capacity(KVA) | Voltage Combination and tap range | connection of transformer winding | No-load loss(W) | Load loss (W) | No-load current (%) | Short circuit impedance (%) | ||
High voltage (KV) |
High voltage tap range ( %) |
Low voltage (KV) |
||||||
50 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 |
20 22 24 |
±5% ±2x2.5% |
0.4 |
Dyn11 Yyn0 |
170 230 270 290 340 410 490 580 690 830 980 1150 1410 1700 |
1270/1210 2120/2020 2500/2380 2970/2830 3500/3330 4160/3960 5010/4770 6050/5760 7280/6930 8280 9900 12150 14670 17550 |
2.0 1.80 1.70 1.60 1.50 1.40 1.40 1.30 1.20 1.10 1.00 1.00 0.90 0.80 |
6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 |
Suppliers with verified business licenses