Warranty: | 2 Years |
---|---|
Phase: | Single |
Output Power: | <50W |
Certification: | CE |
Brand: | Ylk |
Type: | DC/AC Inverters |
Customization: |
---|
Suppliers with verified business licenses
HPM5.6KW All-in-one Charge Solar Inverter
Models
|
NH-HPM5.6KW
|
Parallel mode
|
|
Permitted parallel number
|
1~6
|
AC model
|
|
Rated input voltage
|
220/230Vac
|
Input voltage range
|
(170Vac~280Vac)±2% (90Vac-280Vac)±2% |
Frequency
|
50Hz/ 60Hz(Auto detection)
|
Frequency Range
|
47±0.3Hz~55±0.3Hz(50Hz); 57±0.3Hz~65±0.3Hz(60Hz) |
Overload/short circuit protection
|
Circuit breaker
|
Efficiency
|
>95%
|
Conversion time(bypass and inverter)
|
10ms (typical)
|
AC reverse protection
|
Available
|
Maximum bypass overload current
|
40A
|
Inverter mode
|
|
Output voltage waveform
|
Pure sine wave
|
Rated output power (VA)
|
5600
|
Rated output power (W)
|
5600
|
Power factor
|
1
|
Rated output voltage (Vac)
|
230Vac
|
Output voltage error
|
±5%
|
Output frequency range (Hz)
|
50Hz±0.3Hz 60Hz±0.3Hz |
Maximum Efficiency
|
>92%
|
Peak power
|
10000W
|
Loaded motor capability
|
4HP
|
Rated battery input voltage
|
48V(Minimum starting voltage 44V)
|
Battery voltage range
|
Under voltage alarm/shutdown voltage/over voltage alarm /over voltage recovery.. settable on LCD screen)
|
Power saving mode self-consumption
|
Load≤50W
|
AC charging
|
|
Battery type
|
Lead acid or lithium battery
|
Maximum charge current(can be set)
|
0-60A
|
Charge current error
|
±3Adc
|
Charge voltage range
|
40-60Vdc
|
Short circuit protection
|
Circuit breaker and blown fuse
|
Circuit breaker specifications
|
40A
|
Overcharge protection
|
Alarm and turn off charging after 1 minute
|
PV charging
|
|
Maximum PV open circuit voltage
|
500Vdc
|
PV operating voltage range
|
120-500Vdc
|
MPPT voltage range
|
120-450Vdc
|
Battery voltage range
|
40-60Vdc
|
Maximum PV input power
|
6000W
|
Maximum PV input current
|
22A
|
PV charging current range (can be set)
|
0-80A
|
Charging short circuit protection
|
Blown fuse
|
Wiring protection
|
Reverse polarity protection
|
Hybrid charging Max charger current specifications (AC charger+PV charger)
|
|
Max charger current(can be set)
|
0-80A
|
Certified specifications
|
|
Certification
|
CE(IEC62109-1)/CETL
|
EMC certification level
|
EN61000,C2
|
Operating temperature range
|
-10ºC to 55°ºC
|
Storage temperature range
|
-25ºC~60ºC
|
Humidity range
|
5% to 95%(Conformal coating protection)
|
Noise
|
≤60dB
|
Heat dissipation
|
Forced air cooling, variable speed of fan
|
Communication interface
|
USB/RS485(WiFi/GPRS)/Dry contact control
|
Dimension (L*W*D)
|
426mm*322mm*124mm
|
Weight
|
10.8kg
|
Suppliers with verified business licenses