CSA certificate 300V NMD 90 NMWU90 Building Wires
- 14/2 to 2/3 Indoor Non-Metallic Cable 150m or 75m per reel
Application:
NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or
damp locations.The maximum allowable conductor temperature is 90°C. The minimum
recommended installation temperature is -25°C or -40°C for two-conductor cables and -25°C for
three-conductor cables (with suitable handling procedures). Material should be properly stored
above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended
applications is 300 volts. Consult the Canadian Electrical Code1 for further information related to
applications.
Structure:
1. Conductor: Copper conductor with Copper grounding wire 14AWG to 2AWG
or aluminium alloy 8000series ACM with AL groundig wire Grey 6AWG to 2AWG.
2. Insulation: Polyvinyl chloride (PVC)
3. Protective covering: nylon
4. Jacket: PVC, Heat and moisture-resistant, flame retardant FT1.
5. Number of conductor: 2 parell laid or 3 and 4 round laid
Standard:
CSA C22.2 No. 48 (non-metallic sheathed cable)
CSA File No.:
Master Contract: 271587 ,
Certificate:
80169079
Voltage:
300V
Working temperature:
in dry locations only at temperature not to exceed 90°C.
Performance:
FT-1 Flame retardant; Heat and moisture-resistant
Printing:
HT CABLES c(UL) E487898 14AWG 2C NMD90 NYLON CABLE FT1 300V (-25ºC) xxx m 2023
Jacket Color:
•WHITE - General Residential Wiring
•RED - 2 Black and Red conductors for air condictioner
•ORANGE - No. 10 AWG General Residential Wiring
•YELLOW - No. 12 AWG General Residential Wiring
•BLUE - No. 14 AWG - 2 black and white conductors
Technical data:
Conductor |
Grounding Wire |
Jacket Thickness |
OD |
Weight |
Max. DC resistance at 20C (Ω/km) |
Size AWG |
NO. |
No. of strands |
Insulation Thickness |
Nylon Thickness |
Size ( AWG) |
No. of Strands |
|
mm |
mm |
|
|
mm |
mm |
kg/km |
14 |
2 |
1 |
0.76 |
0.13 |
14 |
1 |
0.76 |
4.9 x 9.9 |
108.9 |
8.62 |
12 |
2 |
1 |
0.76 |
0.13 |
14 |
1 |
0.76 |
5.3 x 11.2 |
148.8 |
5.43 |
10 |
2 |
1 |
0.76 |
0.13 |
12 |
1 |
0.76 |
5.9 x 12.8 |
209.9 |
3.41 |
8 |
2 |
7 |
0.89 |
0.16 |
10 |
1 |
1.14 |
8.1 x 16.4 |
324.1 |
2.14 |
6 |
2 |
7 |
1.14 |
0.2 |
8 |
7 |
1.14 |
9.6 x 20.2 |
487.2 |
1.36 |
14 |
3 |
1 |
0.76 |
0.13 |
14 |
1 |
0.76 |
8.8 |
136.5 |
8.62 |
12 |
3 |
1 |
0.76 |
0.13 |
14 |
1 |
0.76 |
9.8 |
177.9 |
5.43 |
10 |
3 |
1 |
0.76 |
0.13 |
12 |
1 |
0.76 |
11 |
249.7 |
3.41 |
8 |
3 |
7 |
0.89 |
0.16 |
10 |
1 |
1.14 |
14.8 |
418.7 |
2.14 |
6 |
3 |
7 |
1.14 |
0.2 |
8 |
7 |
1.14 |
18.1 |
634.4 |
1.36 |
4 |
3 |
7 |
1.14 |
0.2 |
8 |
7 |
1.52 |
21.4 |
917.3 |
0.848 |
3 |
3 |
7 |
1.14 |
0.2 |
6 |
7 |
2.03 |
24.1 |
1188 |
0.673 |
2 |
3 |
7 |
1.14 |
0.2 |
6 |
7 |
2.03 |
25.8 |
1400.9 |
0.534 |
14 |
3 |
1 |
0.76 |
0.13 |
14 |
1 |
0.76 |
8.8 |
169.2 |
8.62 |
12 |
3 |
1 |
0.76 |
0.13 |
14 |
1 |
0.76 |
9.8 |
222.7 |
5.43 |
10 |
3 |
1 |
0.76 |
0.13 |
12 |
1 |
0.76 |
11 |
316.2 |
3.41 |
8 |
3 |
7 |
0.89 |
0.16 |
10 |
1 |
1.14 |
14.8 |
524.4 |
2.14 |
6 |
3 |
7 |
1.14 |
0.2 |
8 |
7 |
1.14 |
18.1 |
800 |
1.36 |
4 |
3 |
7 |
1.14 |
0.2 |
8 |
7 |
1.52 |
21.4 |
1163.3 |
0.848 |
3 |
3 |
7 |
1.14 |
0.2 |
6 |
7 |
2.03 |
24.1 |
1497.8 |
0.673 |
2 |
3 |
7 |
1.14 |
0.2 |
6 |
7 |
2.03 |
25.8 |
1776.2 |
0.534 |
NMD90 XLPE AL Wire
Application:
NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations.The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C or -40°C for two-conductor cables and -25°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further information related to applications.
Structure:
- Conductor: aluminium alloy 8000series ACM with AL groundig wire Grey 6AWG to 2AWG.
- Insulation: crosslinked polyethylene (XLPE)
- Jacket: PVC, Heat and moisture-resistant, flame retardant FT1.
- Number of conductor: 3 and 4 round laid
Standard:
CSA C22.2 No. 48 (non-metallic sheathed cable)
UL File No.:
E487898
Voltage:
300V
Working temperature:
in dry locations only at temperature not to exceed 90°C.
Performance:
FT-1 Flame retardant; Heat and moisture-resistant
Printing:
HT CABLES c(UL) E487898 6AWG 3C AL ACM NMD90 NYLON CABLE FT1 300V (-25ºC) xxx m 2023
Jacket Color: Grey
Technical data:
Conductor |
Grounding Wire |
Jacket Thickness |
Cable Dimensions |
Weight |
Max. DC resistance at 20C (Ω/km) |
Size AWG |
NO. |
No. of strands |
Insulation Thickness |
Nylon Thickness |
Size ( AWG) |
No. of Strands |
mm |
mm |
mm |
mm |
kg/km |
8 |
3 |
7 |
0.89 |
0.16 |
10 |
1 |
1.14 |
14.8 |
231.8 |
3.52 |
6 |
3 |
7 |
1.14 |
0.2 |
8 |
7 |
1.14 |
18.1 |
337.6 |
2.21 |
4 |
3 |
7 |
1.14 |
0.2 |
8 |
7 |
1.52 |
21.4 |
475.6 |
1.39 |
3 |
3 |
7 |
1.14 |
0.2 |
6 |
7 |
2.03 |
24.1 |
614.7 |
1.1 |
2 |
3 |
7 |
1.14 |
0.2 |
6 |
7 |
2.03 |
25.8 |
701.2 |
0.875 |
8 |
4 |
7 |
0.89 |
0.16 |
10 |
1 |
1.14 |
14.8 |
285.9 |
3.52 |
6 |
4 |
7 |
1.14 |
0.2 |
8 |
7 |
1.14 |
18.1 |
421.4 |
2.21 |
4 |
4 |
7 |
1.14 |
0.2 |
8 |
7 |
1.52 |
21.4 |
591.4 |
1.39 |
3 |
4 |
7 |
1.14 |
0.2 |
6 |
7 |
2.03 |
24.1 |
760.7 |
1.1 |
2 |
4 |
7 |
1.14 |
0.2 |
6 |
7 |
2.03 |
25.8 |
870.6 |
0.875 |