Performance Parameters
Model |
LGDD-12060 |
|
Output |
Dc Voltage |
12V |
Rated Current |
2A /3A/5A |
|
Current Range |
0~5A |
|
Rated Power |
24W/36W/60W |
|
Ripple&Noise(Max) |
150mV |
|
Voltage Tolerance |
±4% |
|
Setup,Rise Time |
100ms/220VAC |
|
Hold Up Time(Typ.) |
80ms/220VAC |
|
Input |
Voltage Range |
100~265VAC |
Frequency Range |
47~60Hz |
|
Power Factor(Typ) |
PF>0.6/220VAC |
|
Efficiency(Typ) |
86% |
|
Short Circuit |
Protection type: recovers automatically after fault conditions is removed |
|
Overlaod |
Overload protection @145~160%above peak rating |
|
|
Over Temperature |
protection typer:shut down o/p voltage.re-power on to recover |
Environment |
Working Temp |
-20~50ºC |
Working Humidity |
20~90% RH no-condensing (Waterproof) |
|
Storage Temp Humidity |
-40~ +60ºC,10~90%RH |
|
Safety&Emc |
Safety Standards |
CE Mark (LVD) |
Withstand Voltage |
I/P-O/P:1.5KVAC IP-GND:1.5KVAC |
NOTE
1. All parameters NOT specially mentioned are measured at 220VAC input,rated laod and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a12''twisted pair-wire terminated with a 0.1uf&10uf parallel capacitor.
3. Tolerance: includes set up tolerance,line regulation and load regulation.