Product Description
Relay & Overload Protector
1.Stable working temperature clear cut action with extention spring,less interference with wireless.
2.Imported raw material,wet-resistant&heat-resisting
3.High precision,steady performance,good synchronism.
4.Widely applied in home appliace compressors and motors for overload or overheat protection.
The Specification (HP) |
1/10HP |
1/8HP |
1/6HP |
1/5HP |
1/4HP |
1/3HP |
1/2HP |
3/8HP |
Applied Power(W) |
74 |
93 |
125 |
150 |
180 |
245 |
370 |
275 |
Overload Current(A) |
5.3 |
5.6 |
6.8 |
8 |
8.7 |
10 |
12 |
11 |
Break Time(S)25ºC |
7-15 |
Applied Temperature(ºC) |
100-400 |
Restored Temperature(ºC) |
50-80 |
The Specification (HP) |
1HP |
1.5HP |
2HP |
Applied Power(W) |
750 |
1100 |
1500 |
Overload Current(A) |
16 |
24 |
30 |
Break Time(S)25ºC |
7-15 |
Applied Temperature(ºC) |
125-155 |
Restored Temperature(ºC) |
50-80 |