Product Description
HHD3E-Pseries motor protector (hereinafter referred to as protector) is applicable to the power supply circuit with AC 50Hz and rated working voltage of AC380V and below, and forms a motor control circuit with AC contactor and other switching appliances. When the main circuit of the motor is in abnormal working conditions such as phase failure and overload, disconnect the contact of the switching appliance in time, disconnect the three-phase power supply of the motor to protect the motor quickly and reliably. The protector adopts the quantitative setting mode of potentiometer, which directly adjusts the setting current of the protector according to the rated current value calibrated on the motor nameplate, which is more convenient and intuitive than the setting mode without quantification and starting the motor, the protector adopts the continuous adjustable technology of starting avoidance, and the overload has excellent inverse time limit performance, which can meet the needs of various motors from light load to heavy load starting. The protector has invention patent.
Product Features
Static quantitative calibration
Static quantitative calibration, without starting the motor, is directly set according to the rated current on the motor nameplate, which is more accurate, intuitive and convenient
Patented power circuit design, wide voltage fluctuation range
For the product with rated voltage AC300-450V, the acceptable fluctuation range is 280-450V; For rated voltage AC220V the acceptable fluctuation range is 130-265V.
The patented phase lost circuit doesn't have the problem of refusal to switch on at no-load, and can be used with automatic control, forward and reverse rotation and other circuit ( such as motor protection for air-compressor).
Application
Widely used for motor protection of CNC machine, air-compressor, air-conditioner, elevator, pump, fans etc, with overload, phase failure, three phase unbalance and locked-rotor protection functions.
With potentiometer quantitative setting, accurary and easy
Adjustable start avoidance time delay, to meet different motor requirement
Patented power circit design, with wide voltage fluctation range
Features
1. Visible scale plate for accuracy setting
2. Special design circuit with anti-moisture, anti-salt-spray and anti-mildew
3. 35mm rail mounting and fixed mounting for selection
Model Selection Guide
Data |
Model |
HHD3E-1P |
HHD3E-2P |
HHD3E-ATP |
HHD3E-AP |
HHD3E-BP |
HHD3E-CP |
HHD3E-DP |
HHD3E-EP |
HHD3E-FP |
Rated Voltage |
AC380V AC220V 50Hz ( other voltage can be customized) |
Current range |
0.2A-1A |
0.4A-2A |
1A-5A |
2A-10A |
8A-40A |
20A-100A |
40A-160A |
120A-300A |
120A-400A |
Start avoidance |
2s-60s adjustable ( during start avoidance phase lost, 3-phase unbalance function active, other function disable. |
Overload action time |
can be customized |
Locked rotor |
≤6s±20% ( when overload current reach 3 times of the setted current) overload light flicking |
Phase lost action time |
≤6s ( when the current of any one phase of the three phase is zero) phase lost light ON |
Three-phase current unbalance |
≤6s ( when the current of any one phase of the three phase is 40%-60% different with other two phase) phase lost light flicking |
Reset time |
Power-off reset and restart interval time ≥10s |
Contact capacity |
3A AC380V (Resistive) |
Mounting method |
Fixed and rail mounting, rail mounting is optional |
Fixed mounting |
Technical Data
Working Power |
AC220V, AC380V 50Hz |
Current Range |
-1P: 0.2-1A;-2P: 0.4-2A; -ATP: 1-5A; -AP: 2-10A; -BP: 8-40A; -CP: 20-100A |
Protection Functions |
Phase loss, 3-phase unbalance, overload, locked rotor, start avoidance |
Display mode |
LED display working status |
Setting mode |
Potentiometer static quantitative setting |
Start avoidance |
2-60s continuous adjustable |
Contact Form |
One set NC contact |
Contact Capacity |
3A AC380V (Resistive) |
Outline Size |
125x66x92mm |
Mounting Method |
Fixed or 35mm rail mounting |
Outline size
Application Example