• Cotrsut Medium PLC Ethercat CPU H56
  • Cotrsut Medium PLC Ethercat CPU H56

Cotrsut Medium PLC Ethercat CPU H56

Task: Program
Structure: Combination
Signal: Continuous
Function: Automatic Control
Certification: RoHS, ISO: 9001, CE
Condition: New
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
CTH3 H56-100S2
Customized
Customized
Weight
0.5kg
Transport Package
CTN
Trademark
COTRUST
Origin
China
HS Code
853710119
Production Capacity
5, 000 Pieces/Year

Product Description

Order Data
 

Model No.

Series

Specification

Order No.

H56-10

CTH-300

H56-10 motion controller:256KBKB PM,1MB DM,32KB DM when power down,24VDC power supply,10DI,6*500KHz high-speed counter,1*EtherNET port.1*USB port,1*CAN port,1*EtherCAT port,1*RS485 port.Support single-axis motion control functions, support interpolation, support electronic CAM and electronic gear and other functions, support C language programming.

CTH3 H56-100S2

 


Performance Parameters

Physical Features
Dimension(W×H×D) 34×115×100 mm
Power dissipation 19.2W
Power Supply Features
Rated input voltage 24V DC
Input voltage rang 20.4V~28.8V DC
Input current    0.8A
Polarity reverse connection protection Yes
Bus power supply voltage +5V DC
Bus power supply current  1.6A
LED Indicator Features
24V power indicator (green) On: 24VDC power supply is normal; Off: No 24VDC power supply
SF indicator(red) On: system failure; Off: no fault
BF indicator(red) On: bus  failure; Off: no fault
FRCE indicator(yellow) On: there is a mandatory item; Off: No item is forced (also can be controlled via the scrapers command)
RMC indicator(green) On: the remote server has been successfully communicated (Ethernet communication port parameters have been configured correctly); Off: failure to communicate with the remote server or disable communication with the remote server (allow and disable communication with the server via the dial switch control)
RUN indicator(green)

On:the system is running; Off: the system stops

STOP indicator(yellow) On: the system stops; OFF = System running
Link1 indicator(green)

On: connection; Off: no connection

SPEED1 indicator(yellow) On:100Mbps;Off:10Mbps
Link2 indicator(green) On: connection; Off: no connection
SPEED2 indicator(yellow) On:100Mbps;Off:10Mbps
I0.0~I1.1(green) On: there is a signal input; Off: no signal input
Instruction performance
Bit instruction execution speed 0.086µs/step
Floating-point instruction execution speed 1.4µs/step
Memory
User program memory 256KB+64KB(Secret memory)
User data memory 1MB
Power down retention memory 32KB
Integrated communication function
Bus interface provides extension module interface
USB port  provides 1*USB main device interface
EtherNET port 1*EtherNET port
RS485 port 1*RS485 port
EtherCAT port 1*EtherCAT port
CAN port 1*CAN port
RS485 port
Number of communication interfaces and protocols 1*RS485 port,PPI/MPI,free port protocol (built-in MODBUS_RTU protocol)
Free port baud rate Baud rate 1.2Kbps~115.2Kbps,built-in Modbus master/slave function
PPI/MPI baud rate 9.6Kbps,19.2Kbps,187.5Kbps
Maximum cable length per segment  Using isolation repeater: 1000m(187.2Kbps)
1200m(38.4Kbps)
No isolation repeater used: 50M
Maximum number of stations  32 for each segment and 126 for each network
Point-to-point (PPI master mode) Yes(NETR/NETW), with a maximum of 8 connections, each connection communicating a maximum of 200 bytes
MPI connection 1 MPI slave station and up to 8 MPI master stations
Isolation Communication port isolation
CANopen port
Communication port 1*CAN port
Maximum number of slave stations  1 master station can be followed by a maximum of 32 slave stations
Protocol type CANopen DS301 standard protocol
Support function  Supports automatic starting of CANopen Manager
Supports optional slave polling
Support to start slave stations
Support the NMT
Support synchronous production
Support synchronous consumption
Support heartbeat generation
Support activation time creation
Transmission rate(kbit/s) 1000 1000 800 500 250 125 50 20
Maximum length (m) 25 25 50 100 250 500 1000 2500
Isolation Communication port isolation
EtherNET port
Communication port 1*EtherNET port
Baud rate 10/100Mbps adaptive
Protocol type Support UDP_PPI protocol, Modbus_TCP /IP master and slave protocol, support Socket free programming, support S7 protocol, support Ethernet programming and Ethernet communication between CPU
Maximum length of each cable 100m connection directly 
Maximum number of  connections per site UDP_PPI supports a maximum of 8 connections
ModBus_TCP supports up to 32 connections,
Socket supports up to 4 connections
 2 UDP, and 2 TCP
User data number Up to 200 bytes for UDP_PPI transmission
Up to 240 bytes are used for ModBus_TCP transport
Maximum of 512 bytes are used for Socket transmission
 
DHCP function Support
Remote monitoring/programming support Support
Isolation Communication port isolation
EtherCAT port
Communication port 1*EtherCAT port
Baud rate 100Mbps adaptive
Protocol type EtherCAT communication protocol
Maximum length of each cable 100m  connection directly 
Maximum number of  connections per site Each master supports up to 64 EtherCAT slave stations
Support function Support for distributed clock configuration, redundancy settings
Support startup parameter configuration
Support for configuring PDO parameters and mappings
Support for configuring bus cycle cycle, configuring startup check vendor ID and product ID
Programming software
Programming software package  Magicworks PLC V2.19 and above version
Programming language  LAD,STL,C  language
Program organization unit
Block types Maximum number maximum capacity per block  Maximum memory
Organization block OB total number of OB tissue blocks is up to 1024 64KB 256KB+64KB
Function FC 64KB
Function block FB 64KB
Data blocks DB 256 64KB 1M
Protection function
Power supply protection Power supply provides reverse connection protection function and surge absorption function
Interface protection Communication port lightning protection
Local I/O expand capabilities
Maximum number of racks 4
Maximum number of modules  Main rack extensions: 11 (power module, CPU, relay module, 8 signal modules)  Slave rack:10(power module, relay module, 8 signal modules) 
Remote I/O expansion capabilities
CAN extends the maximum number of master stations  8
Maximum number of CAN slave stations Each master station CAN connect up to 32 CAN slave stations (277C)
Maximum number of EtherCAT extended slave station Connect up to 64 EtherCAT slave modules, each EtherCAT slave module has a maximum of 8 signal modules
Support motion control function
Motion control function Conforms to the single axis motion control function of PLCopen standard (positioning, speed and return to the original, etc.), linear/arc interpolation function, continuous interpolation function, electronic CAM, electronic gear function.
Support high-level language functions
High-level language  Supports C language programming capabilities
Data area and retention features
Data area type Size Addressing range Addressing property Access property Hold property
Digital Volume Map(I) 256bytes IB0-IB255 Read/write Immediate access/direct access/indirect access  Power down hold data are not supported
Digital volume(Q) 256bytes QB0-QB255 Read/write Immediate access/direct access/indirect access  Power down hold data are not supported
Analog volume (AI) 1024bytes AIW0-AIW1022 Read only Immediate access/direct access/indirect access  Power down hold data are not supported
Analog volume(AQ) 1024bytes AIW0-AIW1022 Write only Immediate access/direct access/indirect access  Power down hold data are not supported
Variable memory(V) 65536bytes VB0-VB65535 Read/write Direct access/indirect access  Support power down hold data
Special memory Area (SM) 2048bytes SMB0-SMB2047 SMB0-SMB29 Read Only/SMB30-SMB2047 Read/write Direct access/indirect access  Power down hold data are not supported
Bit memory(M) 32bytes MB0-MB31 Read/write Direct access/indirect access  Support power down hold data 
Local variable(L) 128bytes LB0-LB127 Read/write Direct access Startup to stop the same call position subroutine can be keep,power down hold data are not supported
Accumulator register(AC) 4 AC0-AC3 Read/write Direct Access Power down hold data are not supported
Step register(S) 32bytes SB0-SB31 Read/write Direct access/indirect access  Power down hold data are not supported
Timer(T) 1ms*36 T0-T2047 - Timing registers can be directly/indirectly accessed, the status bit can only be directly accessed The current count value can be power down hold data, the status bit can not be hold
10ms*752
100ms*1260
Counter(C) 2048 C0-C2047 - Timing registers can be directly/indirectly accessed, the status bit can only be directly accessed The current count value can be power down hold data, the status bit can not be hold
Data block(DB) 512KB - Read/write Direct access/indirect access  16KB power down hold data
Diagnostic function
Number of diagnostic event buffer bars  500, and the oldest one is overwritten when the buffer is full
Number of diagnostic event power down hold 500
The event recording accuracy 1ms
Diagnostic interrupt  Support
Diagnostic LED indication Support
Real time clock
Power-down retention time  Power-down retention time is about 112 hours (typical value), and the power-down retention time can reach at least 1 year after H56 is connected with external battery
Accuracy Less than 60 seconds per month
Interrupt
Timed interrupt  4
Input interrupt 10
High speed counter interrupt  6
Digital input features
Integrated IO 10
Input type  Leak/source
Rated voltage 24V DC
Input voltage range  20.4~28.8V DC
Surge voltage 35V DC,last for 0.5s
Logic 1 signal (min.) 15 VDC,2.5mA
Logic 0 signal (Max)  5 VDC,1mA
Connect 2-wire proximity switch sensor (BERO) 1mA(maximum allowable leakage current)
Input filtering Support 0.2us,0.4us,0.8us,1.6us,3.2us,6.4us,12.8us,0.2ms,0.4ms,0.8ms,1.6ms,3.2ms,6.4ms,12.8ms,default is 6.4ms
Isolation (field and logic) 500V AC,1min
Isolation group See wiring diagram
Simultaneous connection input 10
Maximum cable length 500m(standard input)
Shielded 50m(high speed counter input)
Unshielded 300m(standard input)
Pulse capture input 10
High speed counter Total 6
Single phase 6×500KHz
Two phase 4×250KHz




Cotrsut Medium PLC Ethercat CPU H56
 

Power interface definition

4pin terminals spaced at 3.81mm apart

Symbol

Signal definition

 Cotrsut Medium PLC Ethercat CPU H56

L+

+24V power positive

M

+24V power negative

 

+24V power ground

--

--

 

USB interface definition

USB port

No.

Signal

Signal definition

Cotrsut Medium PLC Ethercat CPU H56

1

V_BUS

+5V power

2

Data-

Data-

3

Data+

Data+

4

GND

Ground

 

EtherNET interface definition

RJ45 port

No.

Signal

Signal definition

 Cotrsut Medium PLC Ethercat CPU H56

1

TX+

Positive end of data transmission

2

TX-

Negative end of data transmission

3

RX+

Positive end of data transmission

4

TERM

--

5

TERM

--

6

RX-

Negative end of data transmission

7

TERM

--

8

TERM

--

Shell

PE

Shell ground

Green indicator

As an indication of EtherNET connection status

Yellow indicator

As an indication of EtherNET connection status

 

 

RS485/CAN interface definition

RJ45 port

No.

Signal

Signal definition

 Cotrsut Medium PLC Ethercat CPU H56

1

CAN_H

Positive end of data transmission

2

CAN_H

Negative end of data transmission

3

-

--

4

A0

RS485 signal A

5

B0

RS485 signal B

6

-

--

7

CAN_GND

CAN_GND signal Ground

8

-

--

Shell

PE

Shell ground

 

Dial switch definition

Dial switch

Symbol

Dial direction

Signal definition

Cotrsut Medium PLC Ethercat CPU H56

RUN

Up

System operation

STOP

Down

System halt

 

Swivel 5 times in 3 seconds

Reset the IP configuration (once from run-> STOP and once from stop-> RUN)

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
2000000 RMB
Plant Area
>2000 square meters