Task: | Program |
---|---|
Structure: | Combination |
Signal: | Continuous |
Function: | Automatic Control |
Certification: | RoHS, ISO: 9001, CE |
Condition: | New |
Customization: |
---|
Suppliers with verified business licenses
Order Data
Model No. |
Specification |
Order No. |
H35-01 |
CTH300-H standard CPU, 192KB PM, 512KB DM,16KB data stored when power down, 2 PPI/Free port, 1 EtherNET port, 1 USB port. |
CTH3 H35-001S2 |
H36-01 |
CTH300-H standard CPU, 256KB PM, 1MB DM,32KB data stored when power down, 1 PPI/Free port, 1 EtherNET port,1 EtherCAT port, 1 USB port.(Recommend) |
CTH3 H36-001S2 |
Performance Parameters
Physical features |
||||
Dimension(W×H×D) |
34×115×101.6 mm |
|||
Power dissipation |
19.5W |
|||
Power supply features |
||||
Rated input voltage |
24V DC |
|||
Input voltage range |
20.4~28.8V DC |
|||
Input current |
0.8A |
|||
Reverse polarity protection |
Yes | |||
Bus power supply voltage |
+5V DC |
|||
Bus supply current |
1.6A |
|||
LED indicator characteristics |
||||
24V power indicator (green) |
On: 24VDC power supply is normal, off: no 24VDC power supply
|
|||
SF indicator (red) |
On: system failure, off: no error |
|||
BF indicator (red) |
On: bus failure, off: no error |
|||
FRCE indicator (yellow) |
On: items are forced, Off: no items are forced.< note > can also be controlled via the scrapers command.
|
|||
RMC indicator (green) |
On: CPU has successfully communicated with the remote server (dial switch 3 is ON and Ethernet port parameters have been configured correctly) Off: CPU fails to communicate with the remote server or disallows communication with the remote server (allows and disallows communication with the server via dialing switch) |
|||
Run indicator (green) |
On:system runs, off: the system stops |
|||
STOP indicator(orange) |
On: system stops; Off: system runs |
|||
Ethernet indicator |
Green |
Flicker: connected, out: unconnected |
||
Yellow |
On:100Mbps,Off:10Mbps |
|||
Expand I/O capabilities |
||||
Maximum number of racks of 1CPU |
4 |
|||
Maximum number of modules supported per rack |
Support up to 8 modules except power, CPU, relay module |
|||
Function category |
Feature |
Describe |
||
Communication function |
Bus interface |
Provides an extension module interface |
||
USB port |
Provide a USB main device interface |
|||
Standard Ethernet interface |
1 Ethernet interface is provided ® supports Ethernet programming; ® supports UDP_PPI protocol: network read and write operation between CPUs (instruction mode UDPNETW/UDPNETR or instruction wizard mode); ® supports Modbus_TCP protocol; |
|||
RS485 port |
H35-00:2*RS485 port H36-00/H36-01:1*RS485 port |
|||
EtherCAT port |
H35-00:None H36-00/H36-01:1*EtherCAT port
|
|||
CANopen port |
H35-00/H36-00:None H36-01:1*CANopen port |
|||
Storage capabilities
|
Program memory |
H35-00:192KB;H36-00/H36-01:256KB |
||
Data storage |
H35-00:512KB;H36-00/H36-01:1MB |
|||
Power down to maintain data |
H35-00:16KB;H36-00/H36-01:32KB |
|||
Expand I/O capabilities |
Expand function |
Maximum expansion of 32 I/O modules (4 racks, 8 modules per rack) |
||
Isolation function |
Power supply isolation |
Isolation between external power and system power |
||
Communication isolation |
EtherNET,EtherCAT,RS485,CANopen isolation |
|||
Protection function |
Power protection |
Power supply end provides reverse connection protection function and surge absorption function |
||
Interface protection |
Communication port lightning protection |
|||
Programming function |
Programming function |
MagicWorks PLC provides LAD ladder diagram, instruction list STL two programming languages, programming software support Chinese/English. |
||
Run switch |
RUN/STOP |
Reset IP configuration by flipping the switch five times within 3 seconds (RUN from run-> STOP, RUN from stop-bbb> |
PORT0:RS485 port |
|||
Number of communication ports and protocols |
RS485 port(switchable PPI and free port protocol) |
||
Communication baud rate |
PPI/MPI:9.6Kbps,19.2Kbps,187.5Kbps |
||
Free port :1.2Kbps~115.2Kbps,built-in Modbus master/slave function |
|||
Maximum cable length per segment |
Use isolation repeater: 1000m (187.5kbps) 1200m(38.4Kbps) No isolation repeater: 50M |
||
Maximum number of stations |
Each segment with 32 stations and each network with 126 stations |
||
Point to point (PPI main station mode) |
Yes (NETR/NETW), each instruction is up to 200 bytes read/write, 8 read/write instructions are allowed at a time |
||
MPI connection |
A MPI slave station can connect up to 8 MPI masters |
||
Isolation |
Communication port isolation |
||
RJ45 port |
|||
Communication protocol |
H35-00 |
H36-00/H36-01 |
H36-01 |
PPI/MPI, free port (Modbus RTU) |
EtherCAT |
CANopen |
|
Communication baud rate |
PPI/MPI:9.6Kbps,19.2Kbps,187.5Kbps |
100Mbps |
20Kbps~1Mbps |
Free port:1.2Kbps~115.2Kbps |
|||
Maximum cable length per segment |
Use isolation repeater: 1000m (187.5kbps) 1200m(38.4Kbps) No isolation repeater: 50M |
100m connection |
Maximum 2500 m (20Kbps) Minimum 25m (1Mbps) Refer to CANopen communication port
|
Maximum number of stations |
Each segment with 32 stations and each network with 126 stations |
No limit |
Each master station support a maximum of 32 slaves |
Point to point (PPI main station mode) |
Yes (NETR/NETW), each instruction is up to 200 bytes read/write, 8 read/write instructions are allowed at a time |
-- |
-- |
MPI connection |
A MPI slave station can connect up to 8 MPI masters |
-- |
-- |
Isolation |
Communication port isolation |
||
EtherNET port |
|||
Communication port |
1*EtherNET port |
||
Baud rate |
10/100Mbps adaptive |
||
Protocol types |
Support UDP_PPI protocol, Modbus_TCP /IP master and slave protocol, support Socket free programming, support Ethernet programming and Ethernet communication between CPU |
||
Maximum length of each cable |
100m directly connected |
||
Maximum number of connections per site |
UDP_PPI supports a maximum of 8 connections, modbus_TCP supports a maximum of 32 connections, Socket supports a maximum of 4 connections, 2 UDP, 2 TCP |
||
Quantity of user data |
Up to 200 bytes for UDP_PPI transfer, Up to 240 bytes for ModBus_TCP transmission, A maximum of 512 bytes are used for Socket transmission
|
||
DHCP function |
Support | ||
Remote monitoring/programming |
Support | ||
Isolation |
Communication port isolation |
CANopen port |
||||||||
Communication port |
-- |
1*CAN port |
||||||
Maximum number of slave stations |
1 master station can be connected maximum of 32 slave stations |
|||||||
Protocol types |
CANopen DS301standard protocol |
|||||||
Support functions |
Supports automatic starting of CANopen Manager |
|||||||
Supports optional slave polling |
||||||||
Support to start slave stations |
||||||||
Support NMT |
||||||||
Support synchronous production |
||||||||
Support synchronous consumption |
||||||||
Support heartbeat generation |
||||||||
Support activation time creation |
||||||||
Transmission rate(kbit/s) |
1000 |
800 |
500 |
250 |
125 |
50 |
20 |
|
Maximum length(m) |
25 |
50 |
100 |
250 |
500 |
1000 |
2500 |
|
Isolation |
Communication port isolation |
Power interface definition
4pin terminals spaced at 3.81mm apart |
Symbol |
Signal definition |
|
L+ |
+24V power |
M |
+24V power ground |
|
|
Ground |
|
-- |
-- |
USB interface definition
USB port |
No. |
Signal |
Signal definition |
1 |
V_BUS |
+5V power |
|
2 |
Data- |
Data- |
|
3 |
Data+ |
Data+ |
|
4 |
GND |
Ground |
EtherNET interface definition
RJ45 port |
No. |
Signal |
Signal definition |
|
1 |
TX+ |
Positive end of data transmission |
2 |
TX- |
Negative end of data transmission |
|
3 |
RX+ |
Positive end of data transmission |
|
4 |
TERM |
-- |
|
5 |
TERM |
-- |
|
6 |
RX- |
Negative end of data transmission |
|
7 |
TERM |
-- |
|
8 |
TERM |
-- |
|
Shell |
PE |
Shell ground |
|
Green indicator |
As an indication of EtherNET connection status |
||
Yellow indicator |
As an indication of EtherNET connection status |
CAN interface definition
RJ45 port |
No. |
Signal |
Signal definition |
|
1 |
CAN_H |
Positive end of data transmission |
2 |
CAN_H |
Negative end of data transmission |
|
3 |
- |
-- |
|
4 |
A0 |
RS485 signal A |
|
5 |
B0 |
RS485 signal B |
|
6 |
- |
-- |
|
7 |
CAN_GND |
CAN_GND signal Ground |
|
8 |
- |
-- |
|
Shell |
PE |
Shell ground |
RS485 interface definition
Port0,use 2pcs of 3pin terminals spaced at 3.81mm apart |
||
6pin terminals |
Signal |
Signal definition |
|
A0 |
PORT0 RS485 signal A |
B0 |
PORT0 RS485 signal B |
|
SG |
PORT0 RS485 signal ground |
|
A0 |
PORT0 RS485 signal A |
|
B0 |
PORT0 RS485 signal B |
|
SG |
PORT0 RS485 signal ground |
Dial switch definition
Dial switch |
Symbol |
Dial direction |
Signal definition |
RUN |
Up |
System operation |
|
STOP |
Down |
System halt |
|
Swivel 5 times in 3 seconds |
Reset the IP configuration (once from run-> STOP and once from stop-> RUN) |
DIP dial |
No. |
Symbol |
Signal definition |
Note |
|
1 |
Term-PORT0 |
Terminal resistance switch 1(PORT0) |
ON:with terminal resistance OFF:without terminal resistance |
2 |
Term-PORT1 (H35-00) |
Terminal resistance switch 2(PORT1) |
ON:with terminal resistance OFF:without terminal resistance |
|
NC (H36-00/H36-01) |
-- |
-- |
||
3 |
RMC-SW |
Remote control switch |
ON:Remote control allow OFF:Remote control forbid |
Suppliers with verified business licenses