Accuracy: 0.02%, 0.05%, 0.1%
Power Supply: One Phase AC 100-265V, Frequency 50/60Hz.
Harmonic Measurment: 2-63times
Communication: RS232 or USB
Transport Package: Aluminium Alloy Box
Specification: CE, ISO9001: 2008, IEC
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Detailed Photos
  • Product Parameters
Overview

Basic Info.

Model NO.
GF102
Trademark
GFUVE
Origin
Beijing, China
HS Code
9030849000
Production Capacity
100units/Month

Product Description

GF102 Portable Single Phase Kwh Meter Testing Set with Power Source
Detailed Photos

Reference Standard Portable Single Phase Kwh Meter Testing Set with Power Source
Reference Standard Portable Single Phase Kwh Meter Testing Set with Power Source

Reference Standard Portable Single Phase Kwh Meter Testing Set with Power Source
Reference Standard Portable Single Phase Kwh Meter Testing Set with Power SourceReference Standard Portable Single Phase Kwh Meter Testing Set with Power SourceReference Standard Portable Single Phase Kwh Meter Testing Set with Power Source
Product Parameters

 


GF102 single phase energy meter testing set used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology. High voltage and current output. Widely used in lab and field.
Features
Meter under testing: 1P2W
Testing mode: Active power, reactive power
Test 3PCS or 2PCS meter synchronously
Starting test and creeping test
Reference standard and power source integrated, easy to carry.
Measuring mechanical meter and electric meter
Operating by manual keyboard or PC
With shortcut key of normal test point, speed up testing
Internal large capacity storage device for mass memory
Local checking the testing result
Overload, short circuit, open circuit protection
With self-checking function
Technical Data
Voltage
Test voltage output (Phase-Neutral)0V~264V
Power of the voltage outputMax. 30VA, 15VA
Resolution0.01%
Accuracy0.1%, 0.2%
Stability0.02%/120s, 0.05%/120s
Distortion factor< 0.3% for linear resistance load
Current
Test current output1mA~120A, 1mA~60A
Power of the current outputMax. 100VA, 30VA
Resolution0.01%
Accuracy0.1%, 0.2%
Stability0.02%/120s
Distortion factor< 0.3% for linear resistance load
Phase angle
Range0 -- 360°
Resolution0.1°
Accuracy0.2°
Frequency
Range45Hz~65Hz
Resolution0.005Hz
Pulse output
High frequency output(CH)1.666× 105 Hz
Low frequency output(CL)5× 10-5× CH
Pulse input
Input channel3
Input frequencyMax. 20Hz
Other
Voltage Supply220V± 10% 50/60Hz± 2Hz
Ambient temperature-10° C -- +40° C
Relative humidity35% -- 85%
Accuracy class 0.02%, 0.05%, 0.1%
Power Supply One Phase AC 100-265V, frequency 50/60Hz.
AC Voltage Output
Range 57.7V, 100V, 220V, 380V; max 600V
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.1% (Non-capacitive load)
Output load 25VA or 50VA
Measuring accuracy 0.02%RG or 0.05%RG
AC Current Output
Range 200mA, 1A, 5A, 20A, 100A; max 120A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.1% (Non-capacitive load)
Output load 50VA or 100VA
Accuracy 0.02%RG or 0.05%RG
Power Output
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.02%RG or 0.05%RG
Reactive power measuring accuracy 0.05%RG or 0.1%RG
Phase Output
Output adjustment range 0°-359.999°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.02°
Power Factor
Adjustment range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0.0005
Frequency Output
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.002Hz
Voltage /Current/Harmonic Setting
Harmonic number 2-63times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy 0.02%RG or 0.05%RG
Reactive power energy 0.05%RG or 0.1%RG
Power Pulse Output
Power pulse type active pulse, reactive pulse
Active power pulse output 5V, 10mA
Power Pulse Input
Energy pulse type support active and reactive pulse, the highest frequency power pulse input is 200K.
Standard
Standard IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016
Safety
Isolation protection IEC 61010-1:2001
Measurement Category 300 V CAT III, 600 V CAT II
Degree of protection IP20
Declaration of conformity CE & CNAS certified
Functions
LCD 7 inch touch TFT color LCD
Communication port RS232 or USB
Programmable Yes
Meter position 1pc or 3pcs
PC control software Optional
Mechanical parameters
Dimensions (W×D×H) (mm) 455x440x150
Weight (kg) 12
Environmental conditions
Ambient temperature -10°C to +40°C
Relative humidity 35%-85%
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
5000000 RMB
Plant Area
>2000 square meters