Walk-in Temperature and Humidity Test Chambers perfectly meet the large size test application that requires high temperature and high humidity. The chamber is constructed with structural steel, the steady structure able to test the large components and products. The various optional function is available for different test standards and requirements.
Features of Walk-in Temperature Humidity Environmental Test Chamber
Environmental Testing Standard
Parameters
Model | BTHW-6M | BTHW-10M | BTHW-15M | BTHW-30M | BTHW-80M |
---|---|---|---|---|---|
Test Space | 2000*2000*1500 | 2500*2000*2000 | 3000*2200*2500 | 5000*2000*3000 | 4000*2500*8000 |
W x H x D (mm) | |||||
External Dimension | 3350*2280*1800 | 3850*2480*2300 | 4350*2480*2800 | 5200*2280*4350 | 4200*2780*9700 |
W x H x D (mm) | |||||
Temperature Range | A:0~90ºC B:-20~90ºC C:-40~90ºC D: -70~90ºC | ||||
Humidity Range | 20%RH-98%RH Low humidity : Maximum 5%R.H. | ||||
Temperature Fluctuation | ≤±0.5ºC | ||||
Temperature Deviation | ≤±2ºC | ||||
Temperature Uniformity | ≤±2ºC | ||||
Humidity Fluctuation | ≤±2.5% | ||||
Humidity Deviation | ≤+2/-3%R.H. (when humidity >75%RH), ≤±5RH% (when humidity <75%RH) | ||||
Heating Rate | Approx 1~ 3ºC/mins,average non-linear ,no load | ||||
Cooling Rate | Approx 0.5~ 1ºC/ mins,average non-linear ,no load | ||||
Temperature Overshoot | ≤±2ºC | ||||
Internal Material | 1.0mm thick SUS#304 high &low temperature resistance stainless steel. | ||||
External Material | 1.2mm thickness High temperature spray powder coated galvanized plate | ||||
Compressor | Tecumseh (France)-fully air-cooled double-fall cooling compressor. Or Bock (Germany) semi-enclosed air-cooled refrigeration. | ||||
Options | Dry air purge system ,Humidifying water auto purifying and supply system, New air ventilation system ,Fire-proof, explosion-proof & alarm system ,Low temperature low humidity, low temperature high humidity test requirement, Remote computer, mobile alarm function |
Precautions for operating walk-in temperature and humidity Environmental Test chamber
According to different names, the walk-in constant temperature and humidity test chamber can also be called constant temperature and humidity chamber, high and low temperature alternating humidity and heat test chamber, etc. It is mainly used for the detection of environmental resistance test materials. It adopts the originally imported controller, which can choose the test mode suitable for you according to your own use requirements.
At the same time, because the walk-in temperature and humidity environmental test chamber is an environmental test chamber that allows operators to enter, it is still dangerous. In order to avoid the occurrence of safety accidents, when we choose to use this walk-in environmental test chamber, we choose to determine whether we are meeting the following conditions.
The above information is about how to correctly use the walk-in constant temperature and humidity test chamber for testing, and hope to help those in need. In the process of using environmental test chambers or battery test chambers for testing, we must first fully understand the operation process of the test chambers, so as to ensure the accuracy of the experimental data and ensure our own personal safety.
Product Name | Complex Salt Spray Test Chamber | |
Model No. | BE-8209-12m³ | BE-8209-15m³ |
Internal Dimension | W2000 X D3000 X H2000 mm | W2500 X D3000 X H2000 mm |
External Dimension | W2400 X D5000 X H3000 mm | W2900 X D5000 X H3000 mm |
Max Load | 1000KG for battery pack | |
Temp. Range | 0ºC~+85ºC | |
Temp. Fluctuation | ±0.5ºC | |
Temp. Deviation | 2ºC | |
Spray Capacity | 1~2mL/80cm2/hr (Collect at least 16 hours, take the average ) | |
Spray Pressure | 1.00±0.01kgf/cm² | |
Resolution | Temp: 0.01ºC, Humidity:0.01%R.H. | |
Humidity Range | 30%-98%R.H.
|
|
Humidity Fluctuation | ±3%R.H. | |
Potion PH | Neutral 6.0~7.0 Acidity 3.0~3.1 | |
Spray Solution PH | Neutral 6.5~7.2 Acidity 3.1~3.3 | |
Test Time Range | 1S ~ 9999H (Settable) | |
Control Mode | Touch screen programmable control PLC, networking; mobile phone APP alarm; with USB interface, with RJ485 interface can be connected to computer control, exclusive network control software. Remote monitoring and data acquisition. | |
Internal material | Acid and alkali resistant SUS316 material | |
External material | Cold and heat resistant steel plate with spray coating | |
Cooling Mode | Air cooling / water cooling | |
Total Weight | Approx 7 Tons | |
Power Supply | AC 380V, 55KW | |
Other Auxiliary Functions | Main-subsidiary type trolley for the specimen in and out of the test chamber.*Explosion-proof, Pressure relief, Smoke Exhaust, Fire extinguishing, Video monitoring. |
Temperature shock
Humidity & Temperature Cycling
Y1: Relative humidity %RH; Y2: Temperature, ºC; X: Time, h;
a: end of the heating; b: cooling start;
c: recommended temperature and humidity values;
d: condensation; e: desiccation; f: 1 cycle.
Standard
Technical Parameters
Product Name | Rapid temperature change rate (damp-heat) Test Chamber |
Model | BTKS5-12m³-C |
Internal Dimension | W2000 X D3000 X H2000mm |
External Dimension | W2400 X D4500 X H2940mm |
Temperature Range | -50ºC ~ +150ºC (Adjustable) |
Humidity Range | 20%RH-98%RH (Limit temperature section, see the regional figure ) |
Temperature Fluctuation | ±0.5ºC |
Humidity Fluctuation | ±2.0%RH |
Temperature Deviation | 2.0ºC |
Humidity Deviation | A) >75%RH: ≤+2, -3%RH, B) <75%RH: ≤±5%RH. |
Heating Rate | >=5ºC/min (From -40ºC up to +80ºC, Non-linear load 800kg) |
Cooling Rate | >=5ºC/min (From -40ºC up to +80ºC, Non-linear load 800kg) |
Temperature overshoot | ≤±2ºC |
Weight | Approx 5 Tons |
Power Supply | AC 380V, 50HZ, 127KW |
Noise | ≤70dB (A-Level) |
External Material | Galvanized sheet with high temperature electrostatic resin coating at both sides. |
Internal Material | 1.2 mm thickness SUS# 304 heat and cold resistant stainless steel with seal welding. |
Controller | 24-bit high accuracy 7 inch TFT true colors LCD touch screen.
|
Compressor | Semi-Hermetic Compressors BOCK / B ITZER (Germany) |
Cooling Type | Air cooling or water cooling (Optional) |
Other Requirement | Main-subsidiary type trolley for the specimen in and out of the test chamber.
Explosion-proof lighting system. Explosion-proof pressure relief system. Smoke exhaust system. Automatic Water Supply System. Fire extinguishing device; spray device; smoke alarm device; |
Model
|
BE-CS-60
|
BE-CS-90
|
BE-CS-120
|
BE-CS-160
|
BE-CS-200
|
Test Space
W x H x D(mm) |
600x400x450
|
900x600x500
|
1200x1000x500
|
1600x1000x500
|
2000x1200x500
|
External Dimension
W x H x D(mm) |
1070x600x1180
|
1310x880x1280
|
1900x1300x1400
|
2300x1300x1400
|
2700x1500x1500
|
Lab Volume
|
108L
|
270L
|
600L
|
800L
|
1440L
|
Brine Tank Capacity
|
15L
|
25L
|
40L
|
40L
|
40L
|
Power Supply
|
AC220V,15A
|
AC220V,15A
|
AC220V,20A
|
AC220V,20A
|
AC220V,30A
|
Test Equipment Temp. Range
|
RT~55ºC
|
||||
Pressure Tank
Temp. Range |
RT~70ºC
|
||||
Temperature Fluctuations
|
≤±0.5ºC
|
||||
Temperature Uniformity
|
≤±2ºC
|
||||
Temperature Precision
|
±1ºC
|
||||
Spray Pressure
|
1.00±0.1kgf/cm²
|
||||
Lab Relative Humidity
|
Above 85%H.R
|
||||
Spray Way
|
Continuous or intermittent type spray(optional)
|
||||
Spray Quantity
|
1.0~2.0ml/80cm²/hour
|
||||
Safety Protection Device
|
Current discharge protection, over pressure protection, over temperature protection, over load fuse protection.
|
Model
|
BE-LY-800
|
BE-LY-1000
|
||
Test Space W x H x D(mm) |
800x800x800
|
1000x1000x1000
|
||
External Dimension W x H x D(mm) |
1160x1640x960
|
1360x1840x1160
|
Test Bench Speed(rpm)
|
1-5 (Adjustable)
|
|||
Turntable Diameter
|
φ 300mm
|
|||
Turntable Load
|
20KG
|
|||
Intermittent be Caught in Time
|
15min/25min
|
|||
Speed
|
5-10 s/rpm
|
|||
Water Ring Radius
|
375mm,pipe diameter Φ16mm
|
|||
cNozzle Jet angle
|
40°,90°,135°fix direction, water spray towards rotary center.
|
|||
Each Spray Hole Flow
|
100±5 L/min(adjustable),flow display direct reading.
|
|||
Water Spray Pressure
|
200-400, a pressure gauge directly reading,
|
|||
Test Time
|
1-999,999min(adjustable)
|
|||
Safety Protection
|
Power overload, short circuit protection, earthling protection, water protection and alarm-ring tip.
|
|||
Power Supply
|
AC220V / 50Hz /1.0KW
|
Application
The Temperature Humidity Vibration Combined Test Chamber meets national standards and meets specific testing requirements. It is widely used in electrical and electronic products, automotive parts, materials, etc. through a combination of high and low temperature, low temperature, temperature change, impact, wet heat vibration and other environmental reliability tests.
Features
Standard Compliance
Performance parameters
Model | BTHZ-408 | BTHZ-800 | BTHZ-1000 |
---|---|---|---|
Internal Dimension | 600x850x800 | 1000x1000x800 | 1000x1000x1000 |
W x H x D(mm) | |||
External Dimension | 850x1650x1500 mm | 1250x1750x1600 | 1250x1750x1800 |
W x H x D(mm) | |||
Temp. Range | B:-20~150ºC C:-40~150ºC D:-70~150ºC | ||
Humidity Range | 20-98%RH | ||
Temp. Fluctuation | ≤±0.5ºC | ||
Temp. Deviation | ≤±2ºC | ||
Temp. Uniformity | ≤±2ºC | ||
Humidity Fluctuation | ≤±2.5%RH | ||
Humidity Deviation |
Temperature 75%RH: ≤+2,-3%RH;Humidity 75%RH: ≤±5%RH |