Polyurethane Fire Proof Spray Foam Insulation Closed Cell Spray Foam Insulation

CAS No.: 9016-87-9
Formula: 9016-87-9
EINECS: 9016-87-9
Appearance: Liquid
Grade Standard: Industrial Grade
Colour: Light Yellow
Samples:
US$ 0/kg 1 kg(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (20)

Basic Info.

Model NO.
ZHD-8006SP
Shelf Life
12 Months
Mixing Ratio
1:1
Viscosity
200-300MPa.S/20ºC(68ºF)
Function
Insulation, Fireproof and Flame Retardant
Transport Package
Steel Drum/IBC/Tank
Specification
200-220KGS/Drum
Trademark
Zibo Huide
Origin
Zibo, China
HS Code
3907299090
Production Capacity
100, 000ton/Year

Product Description

Reaction properties (hand test)

Item Unit Specification
Cream time sec 4-6
Gel time sec 10-20
Free rise density kg/m3 ≥32

Foam properties
Item Unit Specification Test standard
Core density kg/m3 ≥40 ASTM D1622-08
Thermal conductivity, 20ºC W/(m.k) ≤0.024 ASTM C518-10
Compressive strength kPa   200 ASTM D1621-10
Tensile Strength kPa    ≥300 ASTM D1623
Closed cell content     % ≥90 ASTM D6226
Dimensional Stability
28 days, 70ºC, 90%RH
% ≤9 ASTM D2126
Flammability   Class B ASTM E 84
 
Above Data is for reference only.Actual values vary depending on processing conditions and species.
 
4.STORAGE OF MATERIALS
The  materials  are  sensitive  to  humidity  and  partially  used  drums  should  be  tightly  sealed  to
prevent the ingress of moisture.

 
ZHD-8006SP-A (Polyol Blend)
The  Polyol blend has a  shelf life of three  months from  date of manufacture when stored indoors
at temperatures of 20-30°C.  The Polyol blend should be thoroughly mixed before use.

ZHD-8006SP-B (Isocyanate)
The  Isocyanate  has   shelf  life  of  one  year  from  date  of  manufacture  when  stored  indoors  at
temperatures  of  20-30°C.  Avoid  storage  temperatures  of  below  0°C  (as  some  crystallization
may occur) or above 50°C (as formation of insoluble so lids may occur).
SAFTY PRECAUTIONS
Direct contact with ZHD-8006SP can lead to moderate eye irritation and mild skin irritation, which can cause skin allergies. Repeated inhalation of high concentration of volatile gas will cause respiratory allergy, and should be treated immediately. Anti- inflammatory and anti-allergic treatment measures should be taken. Please be careful in the operation to prevent contact with the skin and splash into the eye, please wear the necessary protective equipment (gloves, protective goggles, working clothes, etc.). Once splashed on the skin or the eye, rinse with water immediately for at least 15 minutes, and the skin is washed with soapy water. Please seek medical treatment immediately after swallowed. Notice: This product specification is intended to be used by Shunda Polyurethane Company in order to show sincerity to our customers, while it is not covered by law as a guarantee. Customers can adjust according to the actual operating conditions. If you have any questions, please call our company and we will serve you wholeheartedly.
Polyurethane Fire Proof Spray Foam Insulation Closed Cell Spray Foam Insulation
Polyurethane Fire Proof Spray Foam Insulation Closed Cell Spray Foam InsulationPolyurethane Fire Proof Spray Foam Insulation Closed Cell Spray Foam InsulationPolyurethane Fire Proof Spray Foam Insulation Closed Cell Spray Foam InsulationPolyurethane Fire Proof Spray Foam Insulation Closed Cell Spray Foam InsulationPolyurethane Fire Proof Spray Foam Insulation Closed Cell Spray Foam InsulationPolyurethane Fire Proof Spray Foam Insulation Closed Cell Spray Foam InsulationPolyurethane Fire Proof Spray Foam Insulation Closed Cell Spray Foam Insulation
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now