Certification: | CE |
---|---|
Protection: | Shock Resistance |
Installation: | Vertical |
Housing: | Iron Shell |
Transport Package: | Wood |
Trademark: | VEICHI |
Customization: |
---|
Suppliers with verified business licenses
EHS100 is a new generation integrated servo product that combines control, power, and brakes in one. Simplify installation lines, reduce bridges, wire slots, connectors, and line nodes, reduce equipment complexity, increase space utilization, and increase installation efficiency by more than 5 times.
A new generation of integrated servo products, combining control, power, and braking into one. Simplify installation lines, reduce bridges, wire slots, connectors, and line nodes, reduce equipment complexity, increase space utilization, and increase installation efficiency by more than 5 times.
70,000 hours of the long-life fan (IP65 protection), combined with multi-point temperature detection, intelligent control of fan operation, low load, and long standby conditions are particularly obvious.
Applications: Injection molding machines, molding machines, die-casting machines, blow molding machines, hydraulic presses, bending machines, etc.
>>> Specifications
Project | Specification | ||
Power range | 4,400 W-35,000 W | ||
Power input | Voltage and frequency | Three-phase 380V 50/60HZ | |
Allowable fluctuation range | Voltage: ±15%; frequency fluctuation: ±5% | ||
Distortion rate: meet the requirements of IEC 61800-2 | |||
Closing impulse current | Less than rated current | ||
Drive efficiency | ≥96% | ||
Power Factor | ≥0.94(With DC reactor) | ||
Output | The output voltage | Output under rated conditions: 3-phase, 0~input voltage, error less than 5% | |
Output frequency range | Maximum output frequency: 320HZ | ||
Output speed accuracy | ±0.1% | ||
Overload capacity | 150% rated current 60s, 180% rated current 5s, maximum 2.5 times | ||
Modulation | SVPWM | ||
Carrier frequency range | 2.0~8.0kHz(Model determination) | ||
Digital setting: maximum speed×±0.01% | |||
Analog setting: maximum frequency×±0.2% | |||
Speed resolution | Digital setting: 1rpm | ||
Analog setting: maximum speed×0.05% | |||
Acceleration and deceleration curve | Linear acceleration and deceleration, S curve acceleration and deceleration | ||
Automatic energy saving operation | According to the load condition, the output voltage is automatically optimized to realize energy-saving operation | ||
Automatic current limit | Automatically limit the current during operation to prevent frequent over-current fault trips | ||
Standard function | Oil pressure closed loop control, speed control, RS485, analog output | ||
Speed setting channel | Keyboard digital setting, analog voltage/current terminal AI1, analog voltage/current terminal AI2, analog voltage/current terminal P-AI, communication setting and multi-channel terminal selection, combination of main and auxiliary channels | ||
Feedback input channel | Voltage/current terminal AI1, voltage/current terminal AI2, voltage/current terminal P-AI, communication setting | ||
Run command channel | Operation panel setting, external terminal setting, communication setting | ||
Input command signal | Start, stop, forward and reverse rotation, jog, multi-speed, free stop, reset, acceleration and deceleration time selection, speed setting channel selection, external fault alarm | ||
External output signal | 2 relay outputs; 1 transistor output; 2 analog outputs, voltage output range: 0~10V/0~10V, current output range: 0~20mA/0~20mA | ||
Protective function | Overvoltage, undervoltage, current limit, overcurrent, overload, overheating, data protection | ||
Keyboard display | LED display | Single line 5-digit digital tube display | Can monitor 1 status |
Status monitoring | Pressure command, pressure feedback, speed setting, speed feedback, flow command, output current, output voltage, output torque, output power, bus voltage, module temperature, motor temperature, input terminal X connected state, output terminal Y connected Status etc. | ||
Error alarm | Self-learning abnormality, sensor feedback disconnection, motor overheating, driver overheating, encoder failure, communication failure, overvoltage, undervoltage, overcurrent, short circuit,Phase loss, overload, stall, current limit, data protection damaged, current fault operating status, historical fault | ||
Surroundings | Installation site | Indoor, the altitude is not more than 1000m, no corrosive gas and direct sunlight | |
Temperature and humidity | From -10°C to +40°C | ||
20%-95%RH(No condensation) | |||
vibration | Less than 0.5g | ||
Storage temperature | From -25ºC to +60ºC | ||
Installation method | Wall-mounted, vertical cabinet | ||
Protection level | IP20 | ||
cooling method | Forced air cooling, liquid cooling |