Product model code | BRE-6000-Li/20V/60A/16 | BRE-6000-Li/20V/100A/8 | BRE-6000-Li/20V/200A/8 |
Output per channel | 20V/60A | 20V/100A | 20V/200A |
Channel number | 16 | 8 | 8 |
Channel output access line | Positive and negative current wires for charging and discharging: connected to the positive and negative poles of the battery module. | ||
Voltage detection line: used for voltage detection of the battery module, generally connected to the positive and negative poles of the battery module. | |||
CAN communication interface: used to communicate with the BMS or BMU of the battery module. | |||
Temperature detection interface: optional | |||
Input power | 3phase AC380V ±10%/50Hz | ||
Max input power | 22KW | 18KW | 36KW |
Wiring method of power cabinet | Three-phase five-wire connection |
Power factor of the whole machine | ≥0.99 (Load power is more than 30% of full load power) |
|||
THD of whole machine | THD≤5% | |||
Efficiency | The conversion efficiency of each link is greater than 90% |
|||
Noise | ≤65dB | |||
voltage | Setting range | 0.1V~20V | ||
Min.discharge voltage | 2V~20V;0~20V(custom) | |||
Measurement range | 0V~20V | |||
Resolution | 16 AD | |||
Control accuracy | ±(0.05%RD+0.05%FS) | ±(0.05%RD+0.05%FS) | ||
Measurement accuracy | ±(0.05%RD+0.05%FS) | ±(0.05%RD+0.05%FS) | ||
electric current | Range of charge | 0.1A~60A | 0.1A~100A | 0.1A~200A |
Range of discharge | 0.1A~60A | 0.1A~100A | 0.1A~200A | |
Range of Measurement | 0A~60A | 0A~100A | 0A~200A | |
Resolution | 16 AD,DA | |||
Control accuracy | ±(0.05%RD+0.05%FS) | |||
Control accuracy | ±(0.05%RD+0.05%FS) | |||
Temperature drift coefficient | 25PPM/ºC | |||
Power | Max output power per channel | 1200W | 2000W | 4000W |
Time |
Channel sampling time | 0.1s | ||
Current response time | Maximum current rise time 20ms |
|||
Step setting time range | 1min~1024min | |||
Timer accuracy | ±0.01% | |||
Step setting method | Form edit (Maximum working steps 128) |
|||
Data record | Recording conditions | T:1s~60min | ||
Charge | Charge mode | Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant resistance charging | ||
Stop conditions | Voltage, current, time, capacity, -ΔV, battery module internal circuit protection | |||
Discharge | Discharge mode | Constant current discharge, constant power discharge, constant resistance discharge | ||
Stop conditions | Pack voltage, cell voltage, current, time, capacity, battery module internal circuit protection |
|||
Loop | Number of loop | 1~30000 time | ||
Step per loop | 126 | |||
Protection method | Hardware protection | Short circuit protection | ||
Output voltage surge protection | ||||
Circuit bad contact protection | ||||
Battery voltage double loop measurement protection | ||||
Short circuit protection | ||||
Software protection | Power-down data protection | |||
Offline data protection | ||||
Lower limit voltage, upper limit voltage, lower limit current, upper limit current, upper limit capacity, upper limit temperature parameter setting protection | ||||
Channel features | When the channel is in the state of charging and discharging, when the internal circuit of the load battery module is suddenly disconnected, the output voltage will not overshoot, which can effectively protect the power switching devices inside the module | |||
Double closed-loop structure, constant current and constant voltage conversion can transition smoothly, which can effectively prevent the impact of current spikes and large currents on the battery module, and protect the battery module | ||||
Channel control mode | Each channel can be set and controlled independently | |||
BMS communication per channel | Each channel has an independent CAN communication interface, which can communicate with the BMS or BMU of the battery module, read the relevant data such as the voltage and temperature of the single battery inside the module, and can display it in real time through the central computer or the upper computer | |||
Database | Using SQL, MySQL, ACCESS database to centrally manage test data, compatible with Manufacturing Execution System (MES) for equipment, convenient for data collection of different equipment, delivery of control parameters and debugging and maintenance of communication (database format can be customized according to user requirements) | |||
Data output method | Excel,Txt | |||
Curve type | Able to draw the corresponding relationship curves during the formation process of each battery, including voltage/time curve, current/time curve, capacity/time curve, capacity/voltage curve, etc. | |||
Barcode scanning | Support barcode scanning function, which can be realized through battery barcode | |||
The host computer communication method | TCP/IP protocol | |||
Communication interface | RJ45, 10M~1000M adaptive | |||
System expansion | Expand communication through switches and routers | |||
Cabinet type | Applicable to various battery modules: the cabinet body adopts the terminal output form, the positive and negative poles of the battery module are connected in the form of crocodile clips or wire lugs, and other special connections are proposed by the supplier and specially customized. | |||
Cabinet size | Reference Size:800mm×600×1750mm | |||
IP protection level | IP20 |
Index item | index parameter |
temperature | -10ºC~40ºC Range of working temperature |
-20ºC~60ºC Storage temperature range |
|
Humidity | Working environment relative humidity<=80% RH (no water vapor condensation) |
Storage environment relative humidity<=85% RH (no water vapor condensation) |