• 380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling
  • 380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling
  • 380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling
  • 380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling
  • 380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling

380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling

Application: Industrial, Power Tools, Pumps, Fans, High-Speed Compressors
Operating Speed: High Speed
Operation Mode: Electric Motor
Magnetic Structure: Permanent Magnet
Function: Driving
Structure: Rotating Pole Type (Armature Fixed)
Samples:
US$ 4900/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SRPM290M8F132
Number of Poles
8
Ventilation
Closed
Certification
ISO9001, CE, RoHS
Brand
Mc Motor
Voltage
380VAC-440VAC
Rated Power
132kw
Rated Speed
7000rpm
Cooling Method
Forced-Air
Cooling Fan
230V, 190W, 1540m3/H
Isolation
H
Pole
8
Temp Sensor
1-2PCS on Winding or Bearing
IP
IP54
Rated Torque
180nm
Current
220AMPS
Installation
B3, B5, B35
Usage
Pumps, Fans, High-Speed Compressors
Net Weight
190kg
Customized Range
35-150kw/ 3500-7000rpm
Transport Package
1PC/ Carton ( Wood /Paper Box Optional)
Specification
TBD (based on real motor dimension)
Trademark
mc motor
Origin
China
HS Code
8501520000
Production Capacity
10000 Sets/Year

Product Description

380VAC 132kw 7000rpm High efficiency Permanent Magnetic Electric AC Motor forced air cooling
380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling
Product Feature

1.Suitable for the 15000rpm high speed
2.Reserve a large margin of security
3.High power & high torque
4.High efficiency
5.Small size
6.Low noise low vibration
7.The autonomous patented cooling structure

Specifications
Model type: SRPM290M8F132
Voltage: 380V AC
Rated Power: 132KW
Rated Torque : 180 N.m
Rated speed: 7000rpm
Rated current: around 220
Isolation: H
Water/dust Proof: IP54
Cooling Method: Forced-air
Installation Method: IMB35


Application
High-speed Compressors,Fans,Pumps
380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling

380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling
380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling
Other Models you will be interested in
Motor type Voltage
(V AC)
Rated power
(kW)
Rated torque (N.m) Rated speed
(rpm)
Efficiency
(%)
Duty type  Insulation Ingress protection Pole Number Weight
(kg)
Cooling Method position signal
SRPM160H4XO15 380 15 5.96 24000 96.5 S1 H/F IP67 4 12 Oil  Resolver
SRPM160H4XO75 380 75 35.8 24000 96.5 S1 H/F IP67 4 44 Oil  Resolver
SRPM160H4XO90 380 90 43 24000 96.5 S1 H/F IP67 4 48 Oil  Resolver
SRPM205H4XO110 380 110 52.5 24000 96.5 S1 H/F IP67 4 76 Oil  Resolver
SRPM205H4XO160 380 160 76.4 24000 96.5 S1 H/F IP67 4 86 Oil  Resolver
SRPM205H4XO200 380 200 95.5 24000 96.5 S1 H/F IP67 4 95 Oil  Resolver

380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling380VAC 132kw 7000rpm High Efficiency Permanent Magnetic Electric AC Motor Forced Air Cooling

FAQ
1. Can performanent magnet synchronous motor be used as generator? 

Yes. Permanent magnet synchronous motor  can work as a generator because of its special working theory. If it runs CW as a motor, then runs CCW as a generator. But please kindly note, if when you want to work it as a generator, you need to change a suitable motor controller with AFE function
 
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor? 
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed. 
 
3. Any special technical request on this motor's VFD driver? And Do you have such driver? 
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor. 
 
4. Is there any protective measures to defend permanent magnet rotor from failure? 
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level. 
 
5. Where is this permanent magnet synchronous motor normally used to? 
This permanent magnet synchronous motor is normally used to variable frequency speed situation.
n.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
51
Year of Establishment
2016-10-09