HDGC3932 Cell Battery Activator | |||||||||
Type: HDGC3932 | H393210030 | H393220060 | H393230090 | ||||||
Output | |||||||||
Charge&Discharge Voltage Range | 1.5-15V | ||||||||
Activation cell type | 2V | 6V | 12V | 2V | 6V | 12V | 2V | 6V | 12V |
Charger&Discharge Current Range | 1-100A | 1-60A | 1-30A | 0-200A | 0-120A | 0-60A | 0-300A | 0-180A | 0-90A |
Voltage measurement accuracy | ±0.5%FS+0.01V | ||||||||
Current measurement accuracy | ±1%FS+0.1A Max. range 100A | ||||||||
Cell voltage display accuracy | 0.01V | ||||||||
Current display accuracy | 0.01A | ||||||||
Display | |||||||||
Display Material | Resistive Touchscreen | ||||||||
Display Mode | 7-Inch LCD true color, resolution: 1024*800 | ||||||||
working mode&Data | |||||||||
Working mode | Constant current, constant power, constant voltage, cyclic activation and parallel/slave control possible | ||||||||
Data storage capacity | Built-in: 16Gbit FLASH; external 16G storage | ||||||||
Data communication | USB*1 | ||||||||
Protection performance | |||||||||
Battery side protection | Under-voltage, over-voltage, over-current, over-temperature, short-circuit, reverse connection protection | ||||||||
Audible and visual alarm | Reverse polarity, cut-off condition completion triggers LCD prompt, beep warning | ||||||||
Working conditions | |||||||||
Colling mode | Air cooling | ||||||||
Temperature | Working :- 5~50ºC / Storage:-40~70ºC. | ||||||||
Humidity | Relative humidity: 0~90% (40±2ºC) | ||||||||
Altitude | Available below 4000m | ||||||||
Noise | <75dB | ||||||||
Power Supply | |||||||||
Voltage | Single-phase3-Wire AC220V (-20%-+30%), frequency: 45-65Hz; | ||||||||
Withstand voltage | Input-shell: 2200Vdc 1min / Input-output: 2200Vdc 1min / Output-shell: 700Vdc 1min |